X1400 G2
X1400 G2X1400 G2
X1400 G2
System Unit
System UnitSystem Unit
System Unit
Dimensions
DimensionsDimensions
Dimensions
(H x W x D)
(with bezel)
1.70 x 17.64 x 26.85 in (4.32 x 44.80 x 68.20 cm)
Weight
WeightWeight
Weight
(approximate)
All hard drives, power
supplies, and processors
installed
33.50 lb (15.20kg)
Input Requirements
Input RequirementsInput Requirements
Input Requirements
(per power supply)
Rated Line Voltage
90 - 132 VAC,
180 - 264 VAC
Rated Input Current
6 A (at 100 VAC),
3 A (at 200 VAC)
Rated Input Frequency
47 to 63 Hz
Rated Input Power
486 W (at 100 VAC),
479 W (at 200 VAC)
BTU Rating
BTU RatingBTU Rating
BTU Rating
Maximum
1836 BTU/hr (at 100 VAC),
1706 BTU/hr (at 200 VAC)
System Inlet Temperature
System Inlet TemperatureSystem Inlet Temperature
System Inlet Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
Relative HumidityRelative Humidity
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
Altitude
AltitudeAltitude
Altitude
Operating
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).
Acoustic Noise
Acoustic NoiseAcoustic Noise
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions
were measured in accordance with ISO 7779 (ECMA 74) and declared in
accordance with ISO 9296 (ECMA 109).
Idle
LWAd
6.30 B
QuickSpecs
HP StorageWorks X1000 G2 Network Storage Systems