Hewlett Packard Enterprise BV860A Datasheet Page 48

  • Download
  • Add to my manuals
  • Print
  • Page
    / 54
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 47
LpAm
52.07dBA
Operating
LWAd
6.38 B
LpAm
52.77 dBA
X1500 G2
X1500 G2X1500 G2
X1500 G2
System Unit
System UnitSystem Unit
System Unit
Dimensions
DimensionsDimensions
Dimensions
(H x W x D)
(W/O footstand)
7.87 x 16.81 x 24.13 in (200 x 427 x 613 mm)
Weight
WeightWeight
Weight
(approximate)
All hard drives, power
supplies, and processors
installed
30 kg
Input Requirements
Input RequirementsInput Requirements
Input Requirements
(per power supply)
Rated Line Voltage
100 to 240 VAC
Rated Input Current
7.1 Amps (at 120VAC) to 3.5 Amps (at 240
VAC)
Rated Input Frequency
50 to 60 Hz
Rated Input Power
852 W
BTU Rating
BTU RatingBTU Rating
BTU Rating
Maximum
460W - 1773 BTU / hr (at 120 VAC), 1715
(at 240 VAC)
750W - 2892 BTU / hr (at 120 VAC), 2797
(at 240 VAC)
1200W - 3530 BTU / hr (at 120 VAC), 4600
(at 240 VAC)
System Inlet Temperature
System Inlet TemperatureSystem Inlet Temperature
System Inlet Temperature
Operating
50° to 95° F (10° to 35° C) at sea level with an
altitude derating of 1.8°F per 1,000 ft (1.0° C
per every 305 m) above sea level to a maximum
of 10,000 ft (3050 m) no direct sustained
sunlight . Maximum rate of change is 18°F/hr
(10°C/hr). The upper limit may be limited by the
type and number of options installed. System
performance may be reduced if operating with a
fan fault or above 86°F (30°C).
Non-operating
-22° to 140° F (-30° to 60° C)
Relative Humidity
Relative HumidityRelative Humidity
Relative Humidity
(non-condensing)
Operating
10% to 90% relative humidity (Rh), 82.4°F
(28°C) maximum wet bulb temperature,
noncondensing.
Non-operating
10% to 95% relative humidity (Rh), 101.7°F
(38.7°C) maximum wet bulb temperature,
noncondensing.
Altitude
AltitudeAltitude
Altitude
Operating
10,000 ft (3000m). Maximum allowable altitude
change rate is 1°C per 300m.
Non-operating
10,000 ft (3000m). Maximum allowable altitude
change rate is 1°C per 300m.
QuickSpecs
HP StorageWorks X1000 G2 Network Storage Systems
HP StorageWorks X1000 G2 Network Storage SystemsHP StorageWorks X1000 G2 Network Storage Systems
HP StorageWorks X1000 G2 Network Storage Systems
Technical Specifications
DA - 13839 Worldwide — Version 4 — March 18, 2011