Page view 50
For 460 W Power Supply:
526 W (at 100 VAC),
505 W (at 200 VAC)
BTU Rating
BTU RatingBTU Rating
BTU Rating
Maximum
For 1200 W Power Supply:
3530 BTU/hr (at 100 VAC),
4600 BTU/hr (at 200 VAC)
For 750 W Power Supply:
2925 BTU/hr (at 100 VAC),
2812 BTU/hr (at 200 VAC)
For 460 W Power Supply:
1794 BTU/hr (at 100 VAC),
1725 BTU/hr (at 200 VAC)
Power Specifications
Power SpecificationsPower Specifications
Power Specifications
NOTE:
NOTE: NOTE:
NOTE:
To review typical system power ratings use the HP Power Advisor
which is available online located at url: www.hp.com/go/proliant-energy-
efficient or
www.hp.com/go/hppoweradvisor
Power Supply Output
Power Supply OutputPower Supply Output
Power Supply Output
(per power supply)
Rated Steady-State Power
For 1200 W Power Supply:
800 W (at 100 VAC),
900 W (at 120 VAC),
1200 W (at 200 to 240 VAC)
For 750 W Power Supply:
750 W (at 100 to 120 VAC),
750 W (at 200 to 240 VAC)
For 460 W Power Supply:
460 W (at 100 to 120 VAC),
460 W (at 200 to 240 VAC)
Maximum Peak Power
For 1200 W Power Supply:
800 W (at 100 VAC),
900 W (at 120 VAC),
1200 W (at 200 to 240 VAC)
For 750 W Power Supply:
750 W (at 100 to 120 VAC),
750 W (at 200 to 240 VAC)
For 460 W Power Supply:
460 W (at 100 to 120 VAC),
460 W (at 200 to 240 VAC)
System Inlet Temperature
System Inlet TemperatureSystem Inlet Temperature
System Inlet Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
Relative HumidityRelative Humidity
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
QuickSpecs
HP StorageWorks X1000 G2 Network Storage Systems
HP StorageWorks X1000 G2 Network Storage SystemsHP StorageWorks X1000 G2 Network Storage Systems
HP StorageWorks X1000 G2 Network Storage Systems
Technical Specifications
DA - 13839 Worldwide — Version 4 — March 18, 2011