The HP ProLiant DL380e Gen8 sets the next generation standards of 2U 2-socket rack servers for the industry. With enhanced
configuration flexibility, unmatched performance, and leading energy efficient design the DL380e Gen8 offers the perfect solution for the
dynamic compute and storage requirements of today's demanding datacenters.
Front View:
Rear View:
1.
Quick removal access panel
1.
Slot1 PCIe3 x8 (4, 1)
2.
Redundant Hot Plug Power Supplies(upgradeable option)
2.
Slot2 PCIe3 x16 (8, 4, 1)
3.
Removable Riser Cage assembly
3.
Only for riser board without SAS support: Slot3 PCIe3 x8 (8, 4, 1)
4.
Up to 2 Intel E5-2400 Series Processors
4.
Slot4 PCIe2 x8 (4, 1)
5.
Removable Hot Plug Fans modules, (optional, full N+1
redundancy)
5.
Slot5 PCIe3 x16 (16, 8, 4, 1) (optional)
6.
Optical Disk Drive Bay
6.
Slot6 PCIe3 x16 (8, 4, 1) (optional)
7.
Health LED
7.
Power Supply bay1 (Primary Power Supply)
8.
Network activity LED
8.
Power Supply bay 2 (Shown populated: optional)
9.
Power On /Standby button and system power LED button
9.
Unit ID LED/Button
10.
Unit ID LED
10.
HP Ethernet 1Gb 4-port 366i Adapter (4 x 1GbE)
11.
USB connectors
11.
Service tool
12.
Hard Drive bays
12.
Serial connector
13.
12 DIMM slots: DDR3 Registered(RDIMM), Load Reduced
(LRDIMM) or Unbuffered(UDIMM) memory
13.
Video connector
14.
USB connectors (2)
15.
iLO connector
16.
USB connectors (2)
QuickSpecs
HP ProLiant DL380e Generation 8 (Gen8)
Overview
DA - 14328 North America — Version 15 — December 21, 2012
Page 1
Page view 0
1 2 3 4 5 6 ... 60 61

Summary of Contents

Page 1 - QuickSpecs

The HP ProLiant DL380e Gen8 sets the next generation standards of 2U 2-socket rack servers for the industry. With enhancedconfiguration flexibility,

Page 2

Form FactorOne of the followingdepending on Model2U Rack form factorEntry models ship with fixed rails.All other models ship with sliding rails and ca

Page 3

HP Insight ManagementHP Service Pack forProLiant (SPP)HP Service Pack for ProLiant (SPP) and HP Smart Update Manager (HP SUM)version 5 provide a new,

Page 4

WarrantyThis product is covered by a global limited warranty and supported by HP Services and a worldwidenetwork of HP Authorized Channel Partners res

Page 5

HP Insight ManagementHP Insight ControlHP Insight Control, a product option, delivers essential infrastructuremanagement that can help save time and m

Page 6

High PerformanceClustersHP Cluster PlatformsHP Cluster Platforms are specifically engineered, factory-integrated large-scale ProLiant clusters optimiz

Page 7

HP Simple ConfiguratorSCE is a guided self service tool to help sales and non technical people provide customers with initialconfigurations in 3 to 5

Page 8

Service and SupportHP Technology Services for Industry Standard Servers and BladeSystemCapitalizing on HP ProLiant server and HP BladeSystem capabilit

Page 9

Standard CareStandard Care: Service recommendation that maintains high level of server availabilityHP ProLiant Server Hardware InstallationProvides fo

Page 10

HP Support CenterPersonalized online support portal with access to information, tools and experts to support HP businessproducts. Submit support cases

Page 11

NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - FactoryIntegrat

Page 12

NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - FactoryIntegrat

Page 13

people to use for any installation.WarrantyServer Warranty includes 3-Year Parts, 1-Year Labor, 1-Year Onsite supportwith next business day response.E

Page 14

Base Models - LFFHP ProLiant DL380e Gen8E5-2407 1P 8GB-R HotPlug 8 LFF 460W PS BaseServer668665-001Processor(s)Intel® Xeon® E5-2407 (2.2GHz/4-core/10M

Page 15

Base Models - SFFHP ProLiant DL380e Gen8E5-2407 1P 8GB-R HotPlug 8 SFF 460W PS BaseServer668666-001Processor(s)(1) ) Intel® Xeon® E5-2407 (2.2GHz/4-co

Page 16

High Performance ModelsNOTE: These Models are Energy Star Certified.HP ProLiant DL380e Gen8E5-2450 2P 24GB-R P420Hot Plug 8 SFF 750W PSPerf Svr668669-

Page 17

Storage Models - LFFHP ProLiant DL380e Gen8E5-2420 1P 12GB-R P420Hot Plug 12 LFF 750W PSServer668667-001Processor(s)(1) Intel® Xeon® E5-2420 (1.9GHz/6

Page 18

Power Supply(1) HP 750W CS Gold Hot Plug Power Supply (92% Efficient)Fans4 Hot-Plug Non-redundant FansManagementHP iLO Management Engine (standard)Opt

Page 19

HP ProLiant DL380e Gen8E5-2403 1P 8GB-R HotPlug 8 SFF 2x460W PSServer/S-Buy686202-S01Processor(s)(1) Intel® Xeon® E5-2403 (1.8GHz/4-core/10MB/6.4GT-s

Page 20

Fans6 Hot-Plug Redundant FansManagementHP iLO Management Engine (standard)Form FactorRack (2U)NOTE: Includes Rack Mounting Gen8 telescoping SFF Ball B

Page 21

NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areordered, HP recomm

Page 22

Factory Integrated Model ships with: 2 x HP Smart Socket Guides for fast processor installation.12 DIMM slots for RDIMM, LRDIMM and UDIMM Memory insta

Page 23

ChipsetIntel® C600 Series ChipsetIntel® E5-2400 Processor FamilyNOTE: For more information regarding Intel chipsets, please see the following URL:http

Page 24

P420 or greater controller.Factory Integrated Model ships with: 2 x HP Smart Socket Guides for fast processor installation.12 DIMM slots for RDIMM, LR

Page 25

HP ProcessorsNOTE: If two processors are desired, select one xxxxxx-L21 and one xxxxxx-B21 Entry ProcessorsNOTE: All support up to 1066MHz memory spee

Page 26

HP 4GB (1x4GB) Dual Rank x8 PC3L-10600E (DDR3-1333) Unbuffered CAS-9 LowVoltage Memory Kit647907-B21HP 8GB (1x8GB) Dual Rank x8 PC3-12800E (DDR3-1600)

Page 27

HP I/O Expansion OptionsHP DL380e Gen8 CPU1 with SAS Support FIO Riser Kit661402-B21NOTE: If selected with HP DL380e Gen8 8LFF CTO Chassis, HP DL380eG

Page 28

NOTE: Some options may not be integrated at the factory. Contact your local sales representative for additional information.HP Unique OptionsHP DL380e

Page 29

HP MemoryNOTE: To realize the performance memory capabilities listed in this document, HPSmartMemory is required. For additional information, please s

Page 30

HP Hard DrivesNOTE: The HP ProLiant DL380e Gen8 Smart Storage solutions are equipped withentirely re-designed Small Form Factor (SFF 2.5 in) and Large

Page 31

HP 400GB 6G SAS Mainstream Endurance SFF 2.5-in SC Enterprise Mainstream 3yr WtySolid State Drive690827-B21HP 200GB 6G SAS Mainstream Endurance SFF 2.

Page 32

HP Gen8 2-port SATA Cable KitNOTE: This cable allows the customer to upgrade their B120i-based configuration tosupport up to 6 LFF SATA drives.675856-

Page 33

HP Power SuppliesNOTE: Mixing of power supplies in the same server is not supported. All power suppliesinside a server must be exactly the same model.

Page 34

Maximum Capacity(RDIMM)192GB (12 x 16GB RDIMM @1600MHz or 1333MHz)Maximum Capacity(UDIMM)96GB (12 x 8GB UDIMM @1333MHz)NOTE: HP memory from previous g

Page 35

HP Cooling OptionsHP DL380e Gen8 Hot Plug Fan KitNOTE: This kit contains a single fan and is used to upgrade non-redundantconfigurations to redundant

Page 36

NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use ofan HP approved confi

Page 37

High PerformanceClustersHP Cluster Management Utility HP Insight Cluster Management Utility 1yr 24x7 Flexible LicenseQL803BHP Insight Cluster Manageme

Page 38

HP SecurityHP Trusted Platform Module OptionNOTE: The TPM (Trusted Platform Module) is a microcontroller chip that can securelystore artifacts used to

Page 39

(Smart Array P822 Controller)http://h18000.www1.hp.com/products/quickspecs/13200_na/13200_na.html(Smart Array Advanced Pack)http://h18000.www1.hp.com/

Page 40

HP Tape BackupNOTE: For the complete range of tape drives, autoloaders, libraries and media see:http://www.hp.com/go/tape. For hardware and software c

Page 41

HP Uninterruptible PowerSystemsHP Rack-mountable UPS HP R1500 G3 Uninterruptible Power Supply (UPS) HP R1.5kVA G3 1U NA Uninterruptible Power SystemAF

Page 42

HP Power DistributionUnitsMonitored PDUs HP Monitored Power Distribution Unit: Full Rack Version HP 8.6kVA 24A Single Input Three Phase NA/JP Monitore

Page 43

HP Rack SeriesHP Intelligent Series RackHP 636 1075mm Pallet Intelligent Series RackBW895AHP 636 1075mm Shock Intelligent Series RackBW896AHP 642 1075

Page 44

NOTE: Please see the QuickSpecs for Technical Specifications and additionalinformation:http://h18000.www1.hp.com/products/quickspecs/13475_na/13475_na

Page 45

5PCIe 3.0X16 X16Full length, fullheight slot 6PCIe 3.0X8X16Half length, fullheight slot ** Indicates the number of physical electrical lanes running t

Page 46

HP 3 year 4 hour 24x7 ProLiant DL380e Proactive Care ServiceU6E33EHP 3 year 4 hour 24x7 ProLiant DL380e with Insight Control Proactive Care ServiceU6G

Page 47

For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool:www.hp.com/go/ddr3memory-configuratorMemo

Page 48

There are two(2) DIMM slots for each memory channel; twelve(12) total slots for 2 processors server.Gen8 Supported Memory Bandwidth and CapacityDIMM T

Page 49

CPU #1 IS PROCESSOR ON RIGHT - LOOKING FROM FRONT OF SERVER Channel 1 Channel 2 Channel 3CPU #1slot #1 2 3 4 5 6population orderADBECFIn Order1 4 2 5

Page 50

Following are memory options available from HP: HP MemoryNOTE: To realize the performance memory capabilities listed in this document, HPSmartMemory i

Page 51

AOptical Media Bay optional1-88 x SFF SATA/SAS/SDD Hot Pluggable Hard Drive BaysAOptical Media Bay optional1-88 x LFF SATA/SAS/SDD Hot Pluggable Hard

Page 52

System UnitDimensions - with bezel(H x W x D)SFF Drives: 3.44 x 17.54 x 27.5 in (8.75 x 44.55 x 69.85 cm)LFF Drives: 3.44 x 17.54 x 29.5 in (8.75 x 44

Page 53

For 460 W Power Supply:460 W (at 100 to 120 VAC),460 W (at 200 to 240 VAC)Maximum Peak Power For 1200 W Power Supply:800 W (at 100 VAC),900 W (at 120

Page 54

LWAd5.9 B 5.7 BLpAm42 dBA 41 dBAEmissions Classification(EMC)FCC RatingClass ANormative StandardsCISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15;ICES-00

Page 55

HP Dynamic Smart ArrayB320i ControllerDimensionsEmbeddedDisk Drive Interface -Transfer rateUp to 6Gb/s SAS (Serial Attached SCSI)Up to 6Gb/s SATA (Ser

Page 56

Storage ControllerOne of the followingdepending on ModelEntry Model - SATAHP Dynamic Smart Array B120i ControllerNOTE: Provides support for up to 6 SA

Page 57

HP Ethernet 1Gb 4-port366i AdapterNetwork Interface10Base-T/100Base-TX/1000Base-TXCompatibilityEEE 802.3 10Base-TIEEE 802.3ab 1000Base-TIEEE 802.3u 10

Page 58

© Copyright 2012 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice.Microsoft and Windows N

Page 59

Maximum InternalStorageHot Plug SFF SAS27.0 TB27 x 1TB (with 25SFF drive cage + Rear 2SFF drivecage)Hot Plug SFF SATA27.0 TB27 x 1TB (with 25SFF drive

Page 60

Power SpecificationsTo review typical system power ratings use the HP Power Advisor which is available via the online toollocated at URL: www.hp.com/g

Page 61

System FansOne of the followingdepending on Model4 Hot-Plug Non-redundant Fans ship standard in 1P Models1P: 4 fans - non-redundancy1P: 5 fans - redun