Hewlett Packard Enterprise 666282-B21 Datasheet

Browse online or download Datasheet for Server barebones Hewlett Packard Enterprise 666282-B21. Hewlett Packard Enterprise ProLiant DL160 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 59
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
The HP ProLiant DL160 Gen8 is a dual-socket, high-performance, dense rack server with enhanced manageability and scalability suited
for High Performance Computing (HPC) environments, web serving and other hyperscale environments.
Front View:
Rear View:
1.
Access panel
1.
PCIe 3.0 I/O slot
2.
Power supply (500 Watts multi-output - standard, common
slot power supply factory installable options available)
2.
Integrated Lights-Out Management Engine port
3.
Up to two Intel® Xeon® E5-2600 Series processors
3.
1 GbE LAN port for NIC 1 (RJ-45)
4.
FlexibleLOM slot
4.
1 GbE LAN port for NIC 1 (RJ-45)
5.
Up to 24 DIMM slots: DDR3 Registered (RDIMM), Load
Reduced (LRDIMM) or Unbuffered (UDIMM) memory
5.
Torx tool
6.
Optical Disk Drive Bay
6.
Power supply cable socket
7.
Serial label pull tab
7.
Serial connector
8.
(2) Front USB connectors
8.
Video connector
9.
UID LED button
9.
USB connectors
10.
Power On/Standby button
10.
UID LED button
11.
Health LED
11.
FlexibleLOM slot
12.
Aggregate network LED
13.
Up to 4 LFF SAS/ SATA Hard drives
14.
Up to seven Non hot plug redundant Fans
What's New
Support for NHP LFF CTO Chassis
Includes HP Dynamic Smart Array B120i controller
QuickSpecs
HP ProLiant DL160 Gen8
Overview
DA - 14282 Worldwide — Version 10 — September 24, 2012
Page 1
Page view 0
1 2 3 4 5 6 ... 58 59

Summary of Contents

Page 1 - QuickSpecs

The HP ProLiant DL160 Gen8 is a dual-socket, high-performance, dense rack server with enhanced manageability and scalability suitedfor High Performanc

Page 2

WarrantyThis product is covered by a global limited warranty and supported by HP Services and a worldwidenetwork of HP Authorized Channel Partners. Ha

Page 3

HP Insight managementsoftwareHP Insight ControlHP Insight Control, a product option, delivers essential infrastructuremanagement that can help save ti

Page 4

High PerformanceClustersHP Cluster PlatformsHP Cluster Platforms are specifically engineered, factory-integrated large-scale ProLiant clusters optimiz

Page 5

HP Simple ConfiguratorSCE is a guided self service tool to help sales and non technical people provide customers with initialconfigurations in 3 to 5

Page 6

Service and SupportHP Technology Services for Industry Standard Servers and BladeSystemCapitalizing on HP ProLiant server and HP BladeSystem capabilit

Page 7

Standard Care PackageSupport recommendation that maintains high level of server availabilityHP ProLiant Server Hardware InstallationProvides for the b

Page 8

Warranty / ServiceCoverageFor ProLiant servers and storage systems, the services cover HP-branded hardware options qualified forthe server, purchased

Page 9

NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - FactoryIntegrat

Page 10

Internal StorageUp to 4 large form factor drivesOptical Drive(1) (Optional: DVD-ROM, DVD-RW)Power Supply500W Platinum FIO Power Supply with Backplane

Page 11

Country Code Keyxx=00U.S.xx=29Japanxx=37APDxx=42Euroxx=AAPRCQuickSpecsHP ProLiant DL160 Gen8Pre-configured ModelsDA - 14282 Worldwide — Version 10 —

Page 12

NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - FactoryIntegrat

Page 13

NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areordered, HP recomm

Page 14

(5) Non-hot plug redundant fans(7) USB ports-4 rear, 2 front, 1 internalHP iLO Management Engine (standard)Rack (1U), (1.75 in / 4.45 cm)Power supply

Page 15

and LRDIMM.Registered DIMMs (RDIMMs)HP 4GB (1x4GB) Single Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 LowVoltage Memory Kit647893-B21HP 4GB (1x4G

Page 16

speed is a function of the processor QPI speed.HP Power SuppliesNOTE: Prior to making a power supply selection it is highly recommended that the HPPow

Page 17

HP Storage ControllersSAS ControllersNOTE: One Smart Array Controller is only required when purchasing Hot Plug SFF CTOChassis Model (P/N 666281-B21)

Page 18

NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use ofan HP approved confi

Page 19

HP 4GB (1x4GB) Single Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 LowVoltage Memory Kit647893-B21HP 4GB (1x4GB) Single Rank x4 PC3-12800R (DDR3-1

Page 20

HP Optical DrivesHP 9.5mm SATA DVD ROM JackBlack Optical Drive652238-B21HP 9.5mm SATA DVD RW JackBlack Optical Drive652241-B21HP Hard DrivesNOTE: HP P

Page 21

6G SATA Hot Plug with SmartDrive SFF (2.5-inch) Midline (MDL) Drives HP 500GB 6G SATA 7.2K rpm SFF (2.5-inch) SC Midline 1yr Warranty Hard Drive655708

Page 22

SAS Non-Hot Plug LFF (3.5-inch) Enterprise (ENT) Drives HP 600GB 6G SAS 15K rpm LFF (3.5-inch) Non-hot Plug Dual Port Enterprise 3yrWarranty Hard Driv

Page 23

ChipsetIntel® C600 ChipsetIntel® E5-2600 processor FamilyNOTE: For more information regarding Intel® chipsets, please see the following URL:http://www

Page 24

HP InfiniBandHP InfiniBand 4X QDR ConnectX-2 PCIe G2 Dual Port HCA592520-B21HP InfiniBand FDR/EN 10/40Gb Dual Port 544QSFP Adapter649281-B21HP InfiniB

Page 25

NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use ofan HP approved confi

Page 26

NOTE: For additional license kits including electronic delivery options, please see theInsight Rapid Deployment software QuickSpecs at:http://h18000.w

Page 27

HP I/O AcceleratorOptionsHP 160GB Single Level Cell PCIe ioDrive for ProLiant ServersNOTE: A low-profile PCI bracket is included for use in low-profil

Page 28

HP Smart Array P222/512 FBWC 6Gb 1-port Int/1-port Ext SAS ControllerNOTE: Mini SAS 700mm cable (PN 662963-B21) required with this controller.631667-B

Page 29

HP H220 Host Bus Adapter650933-B21HP H221 Host Bus Adapter650931-B21NOTE: This is a 2 x4 External Port HBA.NOTE: This is only approved for the HP P200

Page 30

HP Disk BackupNOTE: For the complete range of D2D Backup Systems see:http://www.hp.com/go/d2d. For the complete range of RDX drives and media see:http

Page 31

HP Disk Storage SystemsHP Disk Enclosures HP D2600 Disk EnclosureAJ940AHP D2700 Disk EnclosureAJ941ANOTE: Please see the QuickSpecs for additional opt

Page 32

NOTE: Please see the UPS and PDU cable matrix's on the HP Power Protection andManagement page. Under Power Cords, click on the "HP Power Cor

Page 33

NOTE: Please see the UPS and PDU cable matrix's on the HP Power Protection andManagement page. Under Power Cords, click on the "HP Power Cor

Page 34

Network ControllerHP 361i Integrated Dual Port Gigabit Server AdapterExpansion Slots #TechnologyBus WidthConnector Width*Form FactorNotes1PCIe 3.0X16x

Page 35

HP Rack SeriesRack Intelligent Series rackHP 642 1075mm Pallet Intelligent Series RackBW903AHP 642 1075mm Shock Intelligent Series RackBW904ANOTE: It

Page 36

HP USB BFR with PVC Free RU Keyboard/Mouse Kit638214-B21HP USB BFR with PVC Free IN Keyboard/Mouse Kit672097-D63HP USB BFR with PVC Free AP-Intl Keybo

Page 37

HP USB and SD OptionsHP 2GB USB Flash Media Drive Key Kit608447-B21NOTE: HP qualified blank USB key for use with HP ProLiant servers that support theV

Page 38

HP SmartMemoryNew HP SmartMemory now provides additional protection for your servers. With HP Authentication it can verify that you have true HPQualif

Page 39

DIMM slot/capacity/populated speed tableDIMMTypeRegistered DIMMS (RDIMMs)LoadReduced(LRDIMMs)Unbuffered with ECC DIMMs (UDIMMs)DIMMRankSingle Rank (1R

Page 40

Standard and Maximum Memory Capacity (Pre-configured Models)Pre Configured ModelsStandard MemoryMaximum Memory PlusOptional MemoryStandard Memory R

Page 41

CPU1 CPU2 slot #population orderslot #population order Chnl 11A; empty1C; emptyChnl 12E; empty2G; empty3I; 2GB DIMM3K; empty Chnl 24B; emp

Page 42

CPU1 CPU2 slot #population orderslot #population order Chnl 11A; 16GB DIMM1C; emptyChnl 12E; 16GB DIMM2G; empty3I; 16GB DIMM3K; empty Chnl

Page 43

CPU1 CPU2 slot #population orderslot #population order Chnl 11A; 32GB DIMM1A; 32GB DIMMChnl 12E; 32GB DIMM2E; 32GB DIMM3I; 32GB DIMM3I; 32GB DIMM

Page 44

8GB = 8192MB16 GB=16384MB32GB = 32768MB DDR3 memory options part number decoder Following are memory options available from HP:HP MemoryNOTE: HP memo

Page 45

Internal Storage DevicesDiskette DrivesVia USB onlyOptical DrivesOptional SATA 9.5mm DVD-ROM Optical DriveOptional SATA 9.5mm DVD RW Optical DriveDriv

Page 46

HP 2GB (1x2GB) Single Rank x8 PC3-12800E (DDR3-1600) Unbuffered CAS-11 MemoryKit669320-B21HP 2GB (1x2GB) Single Rank x8 PC3L-10600E (DDR3-1333) Unbuff

Page 47

1-4Four LFF Hot-plug SAS/SATA hard drive baysAOptional DVD-ROM, or DVD RW1-8Eight SFF Hot-plug SATA/SAS hard drive baysAOptional DVD-ROM, or DVD RW Dr

Page 48

SAS Hot Plug SmartDrive SFF (2.5-inch) Enterprise Drives QuantitySupportedPositionSupportedController900GB 6G SAS 10K600GB 6G SAS 10K450GB 6G SAS 10K3

Page 49

800GB 6G SAS MLC SSD SFF400GB 6G SAS MLC SSD SFF200GB 6G SAS MLC SSD SFFUp to 81-8HP Smart Array P420/ 1G FBWC controllerHP Smart Array P420/ 2G FBWC

Page 50

External Storage QuantitySupportedPositionSupportedHost Controller or AdapterD2600 Disk EnclosureUp to 4ExternalHP Smart Array P222/512MB FBWC Control

Page 51

HP SCSI Tape Autoloaders1/8 G2 AutoloaderExternalHP SC11Xe Ultra320 Single Channel/ PCIe x4 SCSI Host Bus Adapter412911-B21 HP SCSI Tape Librari

Page 52

System UnitDimensions (H x W x D)(with bezel)4 LFF1.7" (43.2mm) Height x 17.1" (434.6mm) Width x29.5" (750mm) Length8 SFF1.7" (43.

Page 53

sunlight. Maximum rate of change is 10°C/hr(18°F/hr). The upper limit may be limited by thetype and number of options installed.System performance may

Page 54

HP Ethernet 1Gb 2-port361i AdapterNetwork Interface10Base-T/100Base-TX/1000Base-TXCapabilityIEEE 802.3 10Base-TIEEE 802.3ab 1000Base-TIEEE 802.3u 100B

Page 55

Environment-friendlyProducts and ApproachEnd-of-life Managementand RecyclingHewlett-Packard offers end-of-life HP product return, trade-in, and recycl

Page 56

Server Power CordsOne 6' Highline (IEC-IEC) power cord ships standardNOTE: HP ProLiant DL servers no longer ship standard with a 12-foot NEMA 5-1

Page 57

System FansOne of the followingdepending on Model5 non-hot plug redundant fans ship standard in 1P models7 non-hot plug redundant fans ship standard i

Page 58

capability is built into the system (running on the HP iLO chipset) andstarts working the moment that a power cord and an Ethernet cable isconnected t

Page 59

HP Insight managementsoftwareHP Service Pack forProLiant (SPP)HP Service Pack for ProLiant (SPP) and HP Smart Update Manager (HP SUM)version 5 provide

Comments to this Manuals

No comments